DRIVE TYPE | DIRECT |
ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
AIR FLOW RATE | 137.0 CUBIC FEET PER MINUTE NOMINAL |
AMBIENT TEMP AT FULL RATED POWER | -46.0 CELSIUS AND 95.0 CELSIUS |
ENVIRONMENTAL PROTECTION | EXPLOSION PROOF AND MOISTURE RESISTANT AND DUSTPROOF |
FLOW DIRECTION | OUTWARD |
FREQUENCY IN HERTZ | 400.0 |
HOUSING INSIDE DIAMETER | 3.562 INCHES NOMINAL |
INCLOSURE TYPE | FULLY INCLOSED |
LENGTH | 2.340 INCHES NOMINAL |
OPERATING SPEED AT RATED CAPACITY IN RPM | 8225.0 |
MATERIAL | ALUMINUM ALLOY OVERALL |
MOUNTING FACILITY TYPE AND QUANTITY | 1 FLANGE AND 3 UNTHREADED HOLE |
PHASE | SINGLE |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
PRIME MOVER POWER RATING | 60.000 WATTS |
PRIME MOVER TYPE | ELECTRIC MOTOR |
ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
SPECIAL FEATURES | OPERATES AT 50 TO 400 HZ; DESIGNED TO OPERATE AT 290 HZ WITH ROTRON CONVERTER P/N DC34/1 NOT FURNISHED |
SPEED ADJUSTMENTS | SINGLE SPEED |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
STYLE DESIGNATOR | FIXED |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | TT-E-489 FED SPEC SINGLE TREATMENT RESPONSE OVERALL |
SURFACE TREATMENT | ENAMEL OVERALL |
TEST DATA DOCUMENT | 80063-SM-A-586392 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
VOLTAGE IN VOLTS AND CURRENT TYPE | 106.0 AC |