END CONNECTION DESIGN | STRAIGHT 1ST END |
END CONNECTION DESIGN | STRAIGHT 2ND END |
BURST TEST PRESSURE | 20000.0 POUNDS PER SQUARE INCH |
CONNECTION TYPE | EXTERNAL QUICK DISCONNECT 2ND END |
CONNECTION TYPE | INTERNAL QUICK DISCONNECT 1ST END |
CONNECTION STYLE | PUSH (EXTERNAL) 2ND END |
CONNECTION STYLE | PUSH (INTERNAL) 1ST END |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
INSIDE DIAMETER | 0.250 INCHES NOMINAL |
INSIDE SURFACE CONDITION | SMOOTH |
LAYER COMPOSITION AND LOCATION | OUTER LAYER MOLDED PLASTIC AND 1ST LAYER BRAIDED SYNTHETIC CORD |
OUTER COVERING ENVIRONMENTAL PROTECTION | HYDRAULIC SOLUTION RESISTANT AND WEATHERPROOF |
OUTSIDE DIAMETER | 0.500 INCHES NOMINAL |
MAXIMUM OPERATING PRESSURE | 5000.0 POUNDS PER SQUARE INCH |
MEASURING METHOD AND LENGTH | 74.500 INCHES NOMINAL OVERALL |
MINIMUM INSIDE BENDING RADIUS | 4.000 INCHES |
QUICK DISCONNECT NOMINAL SIZE | 0.250 INCHES 1ST END |
QUICK DISCONNECT NOMINAL SIZE | 0.250 INCHES 2ND END |
TEMP RATING | -40.0 FAHRENHEIT AND 200.0 FAHRENHEIT SINGLE RESPONSE |