5910-00-004-6219 CAPACITOR,FIXED,ELECTROLYTIC Index 5935-00-004-6222 BACKSHELL,ELECTRICAL CONNECTOR

National Stock Number:
5905-00-004-6221

Federal Supply Class:
5905

National Item Identification Number:
000046221

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
TM1-8 103K01295TEXAS INSTRUMENTS INCORPORATED


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER100.0 CELSIUS
BODY LENGTH0.406 INCHES NOMINAL
BODY OUTSIDE DIAMETER0.140 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP150.0 CELSIUS
MAXIMUM POWER DISSIPATION RATING125.00 MILLIWATTS
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-5.0 TO 5.0 ALL RESISTANCE-TEMPERATURE POINTS
RELIABILITY INDICATORNOT ESTABLISHED
ZERO POWER RESISTANCE AT SPECIFIED TEMP16.7 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP20.0 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP22.5 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS0.70
ZERO POWER RESISTANCE AT SPECIFIED TEMP4.5 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP5.4 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP6.1 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-5.0 TO 5.0
ZERO POWER RESISTANCE10.000 KILOHMS
STYLE DESIGNATORROD
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-35.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-50.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-65.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER130.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.025 INCHES NOMINAL
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS40.0


Click here to Register for Free 30-day Trial