5905-00-018-2573 RESISTOR,FIXED,WIRE WOUND,INDUCT Index 4720-00-018-2580 HOSE,PREFORMED

National Stock Number:
5905-00-018-2574

Federal Supply Class:
5905

National Item Identification Number:
000182574

Description:
RESISTOR,FIXED,WIRE WOUND,INDUCT

Detail:
INC 37403 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.


Manufacturer Information:
MIL-PRF-26/581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-26/581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RW78U6812F81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL RESISTANCE68.100 KILOHMS
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER275.0
BODY DIAMETER0.344 INCHES MINIMUM AND 0.406 INCHES MAXIMUM
BODY LENGTH1.718 INCHES MINIMUM AND 1.842 INCHES MAXIMUM
CUBIC MEASURE0.197 CUBIC INCHES
INCLOSURE TYPEENCAPSULATED
POWER DISSIPATION RATING IN WATTS10.000 FREE AIR
RELIABILITY INDICATORNOT ESTABLISHED
RESISTANCE TOLERANCE IN PERCENT-1.000 TO 1.000
SPECIFICATION/STANDARD DATA81349-MIL-R-26/5 GOVERNMENT SPECIFICATION
STYLE DESIGNATORAXIAL TERMINAL EACH END
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-30.0 TO 30.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 275.0
TERMINAL LENGTH1.375 INCHES MINIMUM AND 2.125 INCHES MAXIMUM
TERMINAL TYPEWIRE LEAD
TEST DATA DOCUMENT81349-MIL-R-26 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
UNPACKAGED UNIT WEIGHT12.0 GRAMS


Click here to Register for Free 30-day Trial