5935-00-006-7145 CONNECTOR,RECEPTACLE,ELECTRICAL Index 5935-00-006-7149 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5910-00-006-7146

Federal Supply Class:
5910

National Item Identification Number:
000067146

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
2089990-070627914HONEYWELL INTERNATIONAL INC DBA HONEYWELL
CU13CL101UP381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39018-01-018081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39018/01-064481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-39018/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPEPLAIN FOIL
BODY DIAMETER0.383 INCHES NOMINAL
BODY LENGTH2.360 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION100.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALALUMINUM
CASE INSULATION MATERIALPLASTIC
CASE MATERIALMETAL
DC LEAKAGE AT REFERENCE TEMP7.000 MICROAMPERES
DC LEAKAGE AT MAXIMUM OPERATING TEMP20.0 MILLIAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT15.0000
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS30.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION75.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
SPECIFICATION/STANDARD DATA81349-MIL-C-39018/1 GOVERNMENT SPECIFICATION
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-39018 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 30.00 PERCENT SINGLE SECTION