5910-00-020-8006 CAPACITOR,FIXED,MICA DIELECTRIC Index 5935-00-020-8008 JACK,TELEPHONE

National Stock Number:
5910-00-020-8007

Federal Supply Class:
5910

National Item Identification Number:
000208007

Description:
CAPACITOR,FIXED,MICA DIELECTRIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
CET3A11SP23280CUSTOM ELECTRONICS, INC.


Techincal Specification:
SECTION QUANTITY9
CAPACITANCE VALUE PER SECTION0.005 MICROFARADS 1ST SECTION
0.005 MICROFARADS 2ND SECTION
0.010 MICROFARADS 3RD SECTION
0.120 MICROFARADS 4TH SECTION
0.120 MICROFARADS 5TH SECTION
0.068 MICROFARADS 6TH SECTION
0.0033 MICROFARADS 7TH SECTION
0.022 MICROFARADS 8TH SECTION
0.010 MICROFARADS 9TH SECTION
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT ALL SECTIONS
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION900.0 DC 1ST SECTION
1100.0 DC 2ND SECTION
1500.0 DC 3RD SECTION
1700.0 DC 4TH SECTION
2100.0 DC 5TH SECTION
3000.0 DC 6TH SECTION
3000.0 DC 7TH SECTION
3000.0 DC 8TH SECTION
NONDERATED OPERATING TEMP-65.0 DEG CELSIUS MINIMUM AND
125.0 DEG CELSIUS MAXIMUM
BODY STYLEW/THD MTG HOLE(S)/STUD(S), TERMINAL(S) ON ONE SURFACE
BODY LENGTH4.120 INCHES NOMINAL
BODY WIDTH1.050 INCHES MAXIMUM
BODY HEIGHT2.535 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATORONE TERMINAL COMMON TO EACH SECTION
TERMINAL TYPE AND QUANTITY10 SOLDER STUD
TERMINAL LENGTH0.250 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.940 INCHES NOMINAL
CASE MATERIALPLASTIC
MOUNTING FACILITY TYPE AND QUANTITY10 THREADED MOUNTING HOLES
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.112 INCHES
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0.440 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.593 INCHES MINIMUM AND
0.656 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT1.125 INCHES MINIMUM AND
1.875 INCHES MAXIMUM
INSULATION RESISTANCE AT REFERENCE TEMP5000.0 MEGOHM-MICROFARADS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.005
RELIABILITY INDICATORNOT ESTABLISHED
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP25.0 MEGOHM-MICROFARADS