5915-00-005-6965 FILTER,BAND PASS Index 5955-00-005-6967 CRYSTAL UNIT,QUARTZ

National Stock Number:
5915-00-005-6966

Federal Supply Class:
5915

National Item Identification Number:
000056966

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
6580A1517304DAMON CORP ELECTRONICS DIV
930020-1582577RAYTHEON COMPANY
B483AJ1555267RAYTHEON COMPANY DBA RAYTHEON
B483J1527832HUGHES AIRCRAFT CO NEWPORT BEACH DIV
BFN04-1571034BLILEY TECHNOLOGIES INC
F13212-1582567CTS REEVES FREQUENCY PRODUCTS


Techincal Specification:
BODY HEIGHT0.595 INCHES MAXIMUM
BODY LENGTH1.510 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.120 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM 1ST BAND PASS AND 1.5 MAXIMUM 1ST BAND PASS 1ST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM 2ND BAND PASS AND 1.5 MAXIMUM 2ND BAND PASS 2ND FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.235 INCHES MINIMUM AND 1.245 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.840 INCHES MINIMUM AND 0.860 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN GROUND 3RD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 PIN OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION479.65 KILOHERTZ 1ST BAND PASS AND 479.70 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION479.95 KILOHERTZ 2ND BAND PASS AND 480.00 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 1ST BAND PASS 1ST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 2ND BAND PASS 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION162.0 KILOHMS 1ST BAND PASS 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION162.0 KILOHMS 2ND BAND PASS 2ND FUNCTION
OPERATING TEMP RANGE-20.0 TO 71.0 CELSIUS
OVERALL HEIGHT0.695 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY7 TERMINAL
REFERENCE FREQUENCY PER FUNCTION479.975 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
REFERENCE FREQUENCY PER FUNCTION479.675 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION100.0 OHMS 1ST BAND PASS 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION100.0 OHMS 2ND BAND PASS 2ND FUNCTION
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: GM42.000
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION478.875 KILOHERTZ 1ST BAND PASS AND 479.65 KILOHERTZ 1ST BAND PASS AND 479.70 KILOHERTZ 1ST BAND PASS AND 480.475 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION479.175 KILOHERTZ 2ND BAND PASS AND 479.95 KILOHERTZ 2ND BAND PASS AND 480.00 KILOHERTZ 2ND BAND PASS AND 480.775 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0