5915-00-005-8820 FILTER,BAND PASS Index 5915-00-005-8822 FILTER,BAND PASS

National Stock Number:
5915-00-005-8821

Federal Supply Class:
5915

National Item Identification Number:
000058821

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
6580A5817304DAMON CORP ELECTRONICS DIV
930020-5882577RAYTHEON COMPANY
B483AJ5855267RAYTHEON COMPANY DBA RAYTHEON
BFN04-5871034BLILEY TECHNOLOGIES INC
F13212-5882567CTS REEVES FREQUENCY PRODUCTS


Techincal Specification:
BODY HEIGHT0.595 INCHES MAXIMUM
BODY LENGTH1.510 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.120 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM 1ST BAND PASS AND 1.5 MAXIMUM 1ST BAND PASS 1ST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM 2ND BAND PASS AND 1.5 MAXIMUM 2ND BAND PASS 2ND FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.251 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.844 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN GROUND 3RD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 PIN OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION492.40 KILOHERTZ 1ST BAND PASS AND 492.45 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION492.70 KILOHERTZ 2ND BAND PASS AND 492.75 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 1ST BAND PASS 1ST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 2ND BAND PASS 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OPERATING TEMP RANGE-20.0 TO 71.0 CELSIUS
OVERALL HEIGHT0.695 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY9 TERMINAL
REFERENCE FREQUENCY PER FUNCTION492.425 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
REFERENCE FREQUENCY PER FUNCTION492.725 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION491.625 KILOHERTZ 1ST BAND PASS AND 492.40 KILOHERTZ 1ST BAND PASS AND 492.45 KILOHERTZ 1ST BAND PASS AND 493.225 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION491.925 KILOHERTZ 2ND BAND PASS AND 492.70 KILOHERTZ 2ND BAND PASS AND 492.75 KILOHERTZ 2ND BAND PASS AND 493.525 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0


Click here to Register for Free 30-day Trial