1560-00-012-4228 RIB,AIRFOIL Index 5950-00-012-4236 TRANSFORMER,POWER

National Stock Number:
5915-00-012-4231

Federal Supply Class:
5915

National Item Identification Number:
000124231

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
1527-11L8V1MAGNETIKA INC
1527-153342OPT INDUSTRIES INC DIV OF ELECTRONIKA INC
2558160-110001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
55903040POWER CONTROL DEVICES, INC.
P0042A111869ST OLEKTRON CORP


Techincal Specification:
BODY HEIGHT1.000 INCHES MAXIMUM
BODY LENGTH2.000 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.000 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS20.0 MINIMUM 2ND BAND PASS AND 3.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS20.0 MINIMUM 1ST BAND PASS AND 3.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.600 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.600 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN OUTPUT 2ND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 PIN GROUND 3RD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION469.63 KILOHERTZ 1ST BAND PASS AND 469.68 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION469.63 KILOHERTZ 2ND BAND PASS AND 469.68 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.5 1ST BAND PASS 1ST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.5 2ND BAND PASS 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION2.2 KILOHMS 1ST BAND PASS 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION2.2 KILOHMS 2ND BAND PASS 2ND FUNCTION
OPERATING TEMP RANGE-0.0 TO 60.0 CELSIUS
OVERALL HEIGHT1.420 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE50.0 VOLTS AT SEA LEVEL
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.112 INCHES
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCRYSTAL 1ST BAND PASS 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCRYSTAL 2ND BAND PASS 2ND FUNCTION
REFERENCE FREQUENCY PER FUNCTION469.655 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
REFERENCE FREQUENCY PER FUNCTION469.655 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION2.2 KILOHMS 1ST BAND PASS 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION2.2 KILOHMS 2ND BAND PASS 2ND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION469.405 KILOHERTZ 1ST BAND PASS AND 469.63 KILOHERTZ 1ST BAND PASS AND 469.68 KILOHERTZ 1ST BAND PASS AND 469.905 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION469.405 KILOHERTZ 2ND BAND PASS AND 469.63 KILOHERTZ 2ND BAND PASS AND 469.68 KILOHERTZ 2ND BAND PASS AND 469.905 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE