5915-01-361-7692 FILTER,BAND PASS Index 5915-01-361-7694 FILTER,BAND PASS

National Stock Number:
5915-01-361-7693

Federal Supply Class:
5915

National Item Identification Number:
013617693

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
697525120PIEZO TECHNOLOGY INCORPORATED
753-00558997VECTRON INTERNATIONAL, INC.
FA-297654832AEROFLEX LABORATORIES INC COMSTRON DIV
A3060816-00580063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY HEIGHT0.485 INCHES MINIMUM AND 0.515 INCHES MAXIMUM
BODY LENGTH1.485 INCHES MINIMUM AND 1.515 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH0.985 INCHES MINIMUM AND 1.015 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 40.0 MAXIMUM BLANK
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT 1ST FUNCTION1 PIN OUTPUT 2ND FUNCTION2 PIN GROUND 3RD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION2.79985 MEGAHERTZ BLANK AND 2.80015 MEGAHERTZ BLANK
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS2.0 BLANK
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OVERALL HEIGHT0.875 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 TERMINAL
OPERATING TEMP RANGE-35.0 TO 85.0 CELSIUS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCRYSTAL BLANK
REFERENCE FREQUENCY PER FUNCTION2.8 MEGAHERTZ BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION2.7997 MEGAHERTZ BLANK AND 2.79985 MEGAHERTZ BLANK AND 2.80015 MEGAHERTZ BLANK AND 2.8003 MEGAHERTZ BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION2.79985 MEGAHERTZ BLANK AND 2.80015 MEGAHERTZ BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION3.0 BLANK
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 200.0