3120-01-372-3575 BUSHING,SLEEVE Index 5930-01-372-3577 SWITCH,SENSITIVE

National Stock Number:
5915-01-372-3576

Federal Supply Class:
5915

National Item Identification Number:
013723576

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
335-1657088379FRONTGRADE TECHNOLOGIES INC.
664428853711NAVAL SEA SYSTEMS COMMAND
FA407254832AEROFLEX LABORATORIES INC COMSTRON DIV


Techincal Specification:
BODY LENGTH3.940 INCHES MINIMUM AND 3.960 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.870 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.150 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.367 INCHES MINIMUM AND 3.383 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 PIN INPUT 1ST FUNCTION4 PIN OUTPUT 2ND FUNCTION
FEATURES PROVIDEDGAUSSIAN RESPONSE AND ACTIVE AND SHOCK RESISTANT AND FUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT WATER RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION59.97 MEGAHERTZ 1ST BAND PASS AND 65.04 MEGAHERTZ 1ST BAND PASS 1ST FUNCTION59.97 MEGAHERTZ 2ND BAND PASS AND 63.78 MEGAHERTZ 2ND BAND PASS 2ND FUNCTION59.98 MEGAHERTZ 3RD BAND PASS AND 61.89 MEGAHERTZ 3RD BAND PASS 3RD FUNCTION57.14 MEGAHERTZ 4TH BAND PASS AND 62.86 MEGAHERTZ 4TH BAND PASS 4TH FUNCTION
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 1ST BAND PASS 1ST FUNCTION3.0 2ND BAND PASS 2ND FUNCTION3.0 3RD BAND PASS 3RD FUNCTION3.0 4TH BAND PASS 4TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST BAND PASS 1ST FUNCTION50.0 OHMS 2ND BAND PASS 2ND FUNCTION50.0 OHMS 3RD BAND PASS 3RD FUNCTION50.0 OHMS 4TH BAND PASS 4TH FUNCTION
OVERALL HEIGHT0.900 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
OPERATING TEMP RANGE+0.0 TO 70.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION62.5 MEGAHERTZ 1ST BAND PASS 1ST FUNCTION61.88 MEGAHERTZ 2ND BAND PASS 2ND FUNCTION60.94 MEGAHERTZ 3RD BAND PASS 3RD FUNCTION60.0 MEGAHERTZ 4TH BAND PASS 4TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST BAND PASS 1ST FUNCTION50.0 OHMS 2ND BAND PASS 2ND FUNCTION50.0 OHMS 3RD BAND PASS 3RD FUNCTION50.0 OHMS 4TH BAND PASS 4TH FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.7 1ST BAND PASS 1ST FUNCTION1.7 2ND BAND PASS 2ND FUNCTION1.7 3RD BAND PASS 3RD FUNCTION1.7 4TH BAND PASS 4TH FUNCTION
UNTHREADED MOUNTING HOLE DIAMETER0.140 INCHES NOMINAL


Click here to Register for Free 30-day Trial