5970-00-003-8509 INSULATOR,PLATE Index 5998-00-003-8511 HOLDER,ELECTRICAL CARD

National Stock Number:
5945-00-003-8510

Federal Supply Class:
5945

National Item Identification Number:
000038510

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
9274-881558657LEACH INTERNATIONAL CORP
SM-B-58647080063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
DUTY TYPECONTINUOUS
CASE MATERIALMETAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.620 INCHES MINIMUM AND 2.630 INCHES MAXIMUM FIRST MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.620 INCHES MINIMUM AND 2.630 INCHES MAXIMUM SECOND MOUNTING FACILITY
COIL QUANTITY1
CUBIC MEASURE17.124 CUBIC INCHES
ENVIRONMENTAL PROTECTIONHERMETIC AND SHOCK RESISTANT AND VIBRATION RESISTANT
FREQUENCY IN HERTZ60.0 NOMINAL OR 400.0 NOMINAL
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE17.0 AMPERES AC AND 16.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE4.0 AMPERES AC AND 4.0 AMPERES DC LAMP LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE8.0 AMPERES AC AND 8.0 AMPERES DC MOTOR LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP130.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
OVERALL HEIGHT2.540 INCHES NOMINAL
OVERALL LENGTH2.970 INCHES NOMINAL
OVERALL WIDTH2.270 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE FIRST MOUNTING FACILITY
MOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE SECOND MOUNTING FACILITY
MOUNTING FACILITY PATTERNRECTANGULAR SECOND MOUNTING FACILITY
MOUNTING FACILITY PATTERNRECTANGULAR FIRST MOUNTING FACILITY
NOMINAL OPERATING CURRENT RATING AND TYPE100.0 MILLIAMPERES AC SINGLE WINDING
NONPILE-UP MAIN CONTACT ARRANGEMENT4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
WINDING QUANTITY1
TERMINAL TYPE AND QUANTITY14 SCREW ALL FUNCTIONS
TIME DELAY0.02 SECONDS MAXIMUM FIXED OPERATE TIME
TIME DELAY0.05 SECONDS MAXIMUM FIXED RELEASE TIME
UNTHREADED MOUNTING HOLE DIAMETER0.171 INCHES MINIMUM AND 0.183 INCHES MAXIMUM FIRST MOUNTING FACILITY
UNTHREADED MOUNTING HOLE DIAMETER0.171 INCHES MINIMUM AND 0.183 INCHES MAXIMUM SECOND MOUNTING FACILITY