DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES AC RESISTIVE LOAD |
AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 250.0 AC |
COIL QUANTITY | 1 |
CUBIC MEASURE | 21.875 CUBIC INCHES |
ENERGIZING ELEMENT POWER RATING | 2.0 WATTS |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 30.0 AMPERES AC AND 30.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 28.0 DC |
OVERALL HEIGHT | 2.500 INCHES NOMINAL |
OVERALL LENGTH | 3.500 INCHES NOMINAL |
OVERALL WIDTH | 2.250 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
PURPOSE FOR WHICH DESIGNED | GENERAL |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
WINDING DC RESISTANCE RATING | 288.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 8 SCREW ALL FUNCTIONS |
UNTHREADED MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL SINGLE MOUNTING FACILITY |