DUTY TYPE | CONTINUOUS |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.396 INCHES MINIMUM AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 0.312 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
FEATURES PROVIDED | COIL VOLTAGE SUPPRESSION |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC MOTOR LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 12.0 AMPERES DC AND 15.0 AMPERES AC INDUCTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC RESISTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC LAMP LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
OVERALL HEIGHT | 1.010 INCHES MAXIMUM |
OVERALL LENGTH | 1.718 INCHES MAXIMUM |
OVERALL WIDTH | 1.025 INCHES MAXIMUM |
MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 13.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
SPECIAL FEATURES | 3PDT, 25 AMP (RESISTIVE), HERMETICALLY SEALED, 28 VDC COIL, 3% FAILURE RATE, RAISED VERTICAL FLANGE MOUNT, RELAY |
PILE-UP MAIN CONTACT FORM ARRANGEMENT | 3C |
PURPOSE FOR WHICH DESIGNED | GENERAL |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 9 WIRE HOOK CONTACTS |