6130-00-004-0794 POWER SUPPLY Index 3895-00-004-0901 BRAKE BAND AND LINING

National Stock Number:
5950-00-004-0801

Federal Supply Class:
5950

National Item Identification Number:
000040801

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1126347017773BALLISTIC MISSILE DEFENSE SYSTEMS COMMAND
9T35Y718103512GENERAL ELECTRIC CO SPECIALTY TRANSFORMER DEPT


Techincal Specification:
BODY HEIGHT7.100 INCHES NOMINAL
BODY LENGTH9.240 INCHES MAXIMUM
BODY WIDTH8.720 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH8.410 INCHES MINIMUM AND 8.470 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH7.470 INCHES MINIMUM AND 7.530 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT9.590 INCHES NOMINAL
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.355 INCHES MINIMUM AND 0.363 INCHES MAXIMUM SINGLE GROUP
MOUNTING METHODFLANGE AND UNTHREADED HOLE SINGLE GROUP
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT168.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE6.30 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY6 THREADED STUD