5950-00-004-6167 TRANSFORMER,POWER Index 5950-00-004-6169 REACTOR

National Stock Number:
5950-00-004-6168

Federal Supply Class:
5950

National Item Identification Number:
000046168

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
310-13663-0195266OECO, LLC
41358-122558COAST/ADVANCED CHIP MAGNETICS, INC.
4138373386FREED TRANSFORMER CO
86054782577RAYTHEON COMPANY
984656-182577RAYTHEON COMPANY


Techincal Specification:
BODY LENGTH1.130 INCHES MAXIMUM
BODY OUTSIDE DIAMETER2.400 INCHES MAXIMUM
FREQUENCY RATING25.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING FACILITY QUANTITY1 SINGLE GROUP
MOUNTING METHODTHREADED HOLE SINGLE GROUP
NOMINAL THREAD SIZE0.112 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESONE PRIMARY WINDING; TWELVE SEONDARY WINDINGS
WINDING OPERATING CURRENT1.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT100.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT100.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT100.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 12 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE100.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE101.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE15.10 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE42.40 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE69.20 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING POWER RATING4.2 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
WINDING POWER RATING6.9 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
WINDING POWER RATING10.1 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
WINDING POWER RATING15.1 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
TERMINAL TYPE AND QUANTITY39 WIRE LEAD
TEST DATA DOCUMENT82577-984656 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
THREAD SERIES DESIGNATORUNC SINGLE GROUP


Click here to Register for Free 30-day Trial