CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.240 INCHES MINIMUM AND 4.260 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.240 INCHES MINIMUM AND 2.260 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
INCLOSURE TYPE | FULLY INCLOSED |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
OVERALL HEIGHT | 4.500 INCHES MAXIMUM |
OVERALL LENGTH | 5.000 INCHES MINIMUM AND 5.060 INCHES MAXIMUM |
OVERALL WIDTH | 4.000 INCHES MAXIMUM |
MAXIMUM OPERATING TEMP | 85.0 CELSIUS |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING HOLE DIAMETER | 0.210 INCHES MINIMUM AND 0.220 INCHES MAXIMUM SINGLE GROUP |
MOUNTING METHOD | BRACKET AND UNTHREADED HOLE SINGLE GROUP |
SPECIAL FEATURES | 2PRIMARY WINDINGS; 5SECONDARY WINDINGS |
RELIABILITY INDICATOR | NOT ESTABLISHED |
WINDING OPERATING CURRENT | 1.6 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND 5 SECONDARY SINGLE COMPONENT |
WINDING OPERATING CURRENT | 2.2 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
WINDING OPERATING CURRENT | 2.4 AMPERES AC MINIMUM AND 3.1 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
WINDING OPERATING CURRENT | 20.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
WINDING OPERATING VOLTAGE | 114.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
WINDING OPERATING VOLTAGE | 14.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
WINDING OPERATING VOLTAGE | 32.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
WINDING OPERATING VOLTAGE | 8.40 AC VOLTS NOMINAL AND 13.40 AC VOLTS NOMINAL AND 16.80 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
WINDING OPERATING VOLTAGE | 53.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
TERMINAL TYPE AND QUANTITY | 19 SOLDER STUD AND 3 THREADED STUD |
TEST DATA DOCUMENT | 57057-8892400014 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |