5950-01-369-1474 TRANSFORMER,POWER Index 5950-01-369-1476 TRANSFORMER,POWER

National Stock Number:
5950-01-369-1475

Federal Supply Class:
5950

National Item Identification Number:
013691475

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
34013S657TRANSISTOR DEVICES INC DBA FERNWOOD MAGNETICS DIV DIV CIRCUITEK DIVISION
3493209004TRANSISTOR DEVICES INC


Techincal Specification:
BODY LENGTH1.780 INCHES MAXIMUM
BODY WIDTH1.660 INCHES MAXIMUM
FREQUENCY RATING40.0 KILOHERTZ MINIMUM AND 60.0 KILOHERTZ MAXIMUM ALL COMPONENTS
INCLOSURE TYPEOPEN
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE ALL COMPONENTS
MAXIMUM OPERATING TEMP68.0 CELSIUS
MOUNTING FACILITY QUANTITY1 SINGLE GROUP
MOUNTING HOLE DIAMETER0.220 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIFICATION/STANDARD DATA09004-34932 MANUFACTURERS SOURCE CONTROL
WINDING OPERATING CURRENT12.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY1.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY10.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY ALL COMPONENTS
WINDING OPERATING VOLTAGE25.00 AC VOLTS MINIMUM AND 35.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL ALL COMPONENTS
TERMINAL TYPE AND QUANTITY7 WIRE LEAD