5955-00-003-2419 CRYSTAL UNIT,QUARTZ Index 5945-00-003-2489 RELAY,ELECTROMAGNETIC

National Stock Number:
5955-00-003-2486

Federal Supply Class:
5955

National Item Identification Number:
000032486

Description:
CRYSTAL UNIT,QUARTZ

Detail:
An item which consists of a quartz crystal resonator(s), suitably mounted in a HOLDER, QUARTZ CRYSTAL.


Manufacturer Information:
CR-150/U84.025000MHZ81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CR150/U84M0250081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CR150U00136MICROSEMI CORP. - HIGH PERFORMANCE TIMING
MIL-PRF-3098/13181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC3098-13181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DRIVE LEVEL RATING0.8 MILLIWATTS MINIMUM AND 1.2 MILLIWATTS MAXIMUM
BODY LENGTH0.750 INCHES MINIMUM AND 0.775 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS0.478 INCHES MINIMUM AND 0.494 INCHES MAXIMUM
CIRCUIT RESONANCESERIES RESONANCE
CONTROLLED REFERENCE TEMP75.0 CELSIUS
EQUIVALENT RESISTANCE VALUE IN OHMS40.0 NOMINAL
FREQUENCY TOLERANCE FOR OPERATING TEMP IN PERCENT-0.0005 TO 0.0005
OPERATING TEMP RANGE+70.0 TO 80.0 CELSIUS
OVERALL LENGTH0.973 INCHES MINIMUM AND 1.023 INCHES MAXIMUM
OVERALL THICKNESS0.352 INCHES MAXIMUM
OVERALL WIDTH0.757 INCHES MAXIMUM
MODE OF OSCILLATIONFIFTH OVERTONE
OPERABLE TEMP RANGE-55.0 TO 70.0 CELSIUS
SHUNT CAPACITANCE IN PICOFARADS3.0 MAXIMUM
SPECIFIED FREQUENCY84.025 MEGAHERTZ
STYLE DESIGNATORHAT TYPE, 5 WIRE LEADS
TERMINAL LENGTH0.223 INCHES MINIMUM AND 0.248 INCHES MAXIMUM
TERMINAL DIAMETER0.048 INCHES MINIMUM AND 0.052 INCHES MAXIMUM
TEST DATA DOCUMENT81349-MILC3098 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Click here to Register for Free 30-day Trial