6130-00-004-9417 INVERTER,PULSE,RADIO FREQUENCY Index 5845-00-004-9422 COIL ASSEMBLY,DEFLE

National Stock Number:
5985-00-004-9420

Federal Supply Class:
5985

National Item Identification Number:
000049420

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
20500354647MICROTECH INC
227033610001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER


Techincal Specification:
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE DEPTH0.360 INCHES MINIMUM AND 0.390 INCHES MAXIMUM SECOND FLANGE
FLANGE DEPTH0.922 INCHES MINIMUM AND 0.953 INCHES MAXIMUM FIRST FLANGE
FLANGE CONNECTING FACILITY AND QUANTITY8 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING FACILITY AND QUANTITY8 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING HOLE DIAMETER0.199 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE INSIDE HEIGHT0.867 INCHES MINIMUM AND 0.877 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE HEIGHT1.002 INCHES MINIMUM SECOND FLANGE
FLANGE INSIDE WIDTH1.867 INCHES MINIMUM AND 1.877 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE WIDTH2.002 INCHES MINIMUM SECOND FLANGE
FLANGE OUTSIDE DIAMETER3.610 INCHES MINIMUM AND 3.640 INCHES MAXIMUM FIRST FLANGE
FLANGE OUTSIDE DIAMETER3.610 INCHES MINIMUM AND 3.640 INCHES MAXIMUM SECOND FLANGE
FLANGE QUANTITY2
FLANGE STYLECHOKE TYPE FIRST FLANGE
FLANGE STYLECOVER TYPE SECOND FLANGE
FLEXIBILITYFLEXIBLE SINGLE TUBING SEGMENT
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
MATERIALALUMINUM ALLOY ALL FLANGE
MATERIALCOPPER ALLOY SINGLE TUBING SEGMENT
MAXIMUM OPERATING PRESSURE15.0 POUNDS PER SQUARE INCH GAGE
NOMINAL THREAD SIZE0.190 INCHES FIRST FLANGE ALL CONNECTION FACILITIES
PRECIOUS MATERIAL AND LOCATIONEXTERNAL TUBING SURFACES SILVER
PRECIOUS MATERIALSILVER
SPECIAL FEATURESOPERATING FREQUENCY RANGE 5.4 TO 5.9 GHZ; TEMPERATURE RANGE MINUS 65.0 TO PLUS 75.0 DEG C
SPECIFICATION/STANDARD DATA10001-2270336 MANUFACTURERS SPECIFICATION CONTROL
VOLTAGE STANDING WAVE RATIO1.08
WAVEGUIDE INSIDE HEIGHT0.867 INCHES MINIMUM AND 0.877 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH1.867 INCHES MINIMUM AND 1.877 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH1.995 INCHES MINIMUM AND 2.005 INCHES MAXIMUM
WAVEGUIDE LONGER OFFSET DISTANCE11.287 INCHES MINIMUM AND 11.407 INCHES MAXIMUM
WAVEGUIDE OFFSET DISTANCE10.876 INCHES MINIMUM AND 11.000 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.995 INCHES MINIMUM AND 1.005 INCHES MAXIMUM
STYLE DESIGNATORBEND TYPE
SURFACE TREATMENTCHROMATE ALL FLANGE OUTSIDE SURFACES
SURFACE TREATMENTRUBBER AND SILVER SINGLE TUBING SEGMENT OUTSIDE SURFACES
THREAD CLASS2B FIRST FLANGE ALL CONNECTION FACILITIES
THREAD DIRECTIONRIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
THREAD QUANTITY PER INCH32 FIRST FLANGE ALL CONNECTION FACILITIES
THREAD SERIES DESIGNATORUNF FIRST FLANGE ALL CONNECTION FACILITIES
TUBING WALL CONSTRUCTION STYLESEAMLESS SINGLE TUBING SEGMENT