5950-00-006-9131 REACTOR Index 5935-00-006-9134 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5985-00-006-9132

Federal Supply Class:
5985

National Item Identification Number:
000069132

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
FG112CCCB4081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M287/5-36-040081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-DTL-287/581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-W-287/581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE DEPTH0.438 INCHES NOMINAL SECOND FLANGE
FLANGE DEPTH0.625 INCHES NOMINAL FIRST FLANGE
FLANGE CONNECTING FACILITY AND QUANTITY4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING HOLE DIAMETER0.169 INCHES NOMINAL SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE INSIDE DIAMETER1.159 INCHES NOMINAL FIRST FLANGE
FLANGE INSIDE HEIGHT0.497 INCHES NOMINAL FIRST FLANGE
FLANGE INSIDE HEIGHT0.628 INCHES NOMINAL SECOND FLANGE
FLANGE INSIDE WIDTH1.122 INCHES NOMINAL FIRST FLANGE
FLANGE INSIDE WIDTH1.253 INCHES NOMINAL SECOND FLANGE
FLANGE OUTSIDE HEIGHT1.875 INCHES NOMINAL FIRST FLANGE
FLANGE OUTSIDE HEIGHT1.875 INCHES NOMINAL SECOND FLANGE
FLANGE OUTSIDE WIDTH1.875 INCHES NOMINAL FIRST FLANGE
FLANGE OUTSIDE WIDTH1.875 INCHES NOMINAL SECOND FLANGE
FLANGE QUANTITY2
FLANGE STYLECHOKE TYPE FIRST FLANGE
FLANGE STYLECOVER TYPE SECOND FLANGE
FLEXIBILITYFLEXIBLE SINGLE TUBING SEGMENT
INSERTION LOSS IN DECIBELS0.42
MATERIALCOPPER ALLOY ALL TUBING SEGMENT AND FLANGE
MATERIALRUBBER NATURAL SINGLE TUBING JACKET
MAXIMUM OPERATING PRESSURE45.0 POUNDS PER SQUARE INCH GAGE
NOMINAL THREAD SIZE0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES
SPECIFICATION/STANDARD DATA81349-MIL-W-287/5 GOVERNMENT SPECIFICATION
VOLTAGE STANDING WAVE RATIO1.15
WAVEGUIDE INSIDE HEIGHT0.497 INCHES NOMINAL
WAVEGUIDE INSIDE WIDTH1.122 INCHES NOMINAL
WAVEGUIDE LENGTH3.333 FEET NOMINAL
WAVEGUIDE OUTSIDE HEIGHT0.625 INCHES NOMINAL
WAVEGUIDE OUTSIDE WIDTH1.250 INCHES NOMINAL
STYLE DESIGNATORSTRAIGHT TYPE
SURFACE TREATMENTENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
THREAD CLASS2B FIRST FLANGE ALL CONNECTION FACILITIES
THREAD DIRECTIONRIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
THREAD QUANTITY PER INCH32 FIRST FLANGE ALL CONNECTION FACILITIES
THREAD SERIES DESIGNATORUNC FIRST FLANGE ALL CONNECTION FACILITIES
TUBING WALL CONSTRUCTION STYLEINTERLOCKED SINGLE TUBING SEGMENT


Click here to Register for Free 30-day Trial