5836-01-361-4971 CONTROL,RECORDER-REPRODUCER Index 5955-01-361-4973 OSCILLATOR,CRYSTAL CONTROLLED

National Stock Number:
5996-01-361-4972

Federal Supply Class:
5996

National Item Identification Number:
013614972

Description:
AMPLIFIER,RADIO FREQUENCY

Detail:
An electronic device whose radio frequency input signals control power from a source independent of the input signals, and delivers radio frequency output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It operates at frequencies above 20 kilohertz.


Manufacturer Information:
8010H02F0001L7Y9DYNAMIC WAVE TELECOM INC.
8010H02F00073293STELLANT SYSTEMS INC


Techincal Specification:
AVERAGE LIFE MEASUREMENTNOT RATED
AVERAGE POWER RATING PER CHANNEL10.0 WATTS OUTPUT
BASIC SHAPE STYLERECTANGULAR OR SQUARE
CIRCUIT CONSTRUCTION TYPESOLID STATE
CONNECTION CONTACT TYPE AND QUANTITY1 RECEPTACLE, COAXIAL INTERNAL
CONNECTION TYPETERMINAL STUD FRONT
CONTROL TYPELOCAL
CUBIC MEASURE0.73 CUBIC FEET
EXTERNAL AC OPERATING VOLTAGE IN VOLTS99.0 MINIMUM SINGLE VOLTAGE AND 132.0 MAXIMUM SINGLE VOLTAGE
FREQUENCY PER CHANNEL4.0 GIGAHERTZ NOMINAL OPERATING CHANNEL AND 8.0 GIGAHERTZ NOMINAL OPERATING CHANNEL
INCLOSURE MATERIALALUMINUM
INCLOSURE TYPEENCASED
INSTALLATION DESIGNTOP OF CABINET/COUNTER AND RACK
OVERALL GAIN30.0 DECIBELS
OVERALL HEIGHT3.500 INCHES NOMINAL
OVERALL LENGTH21.240 INCHES NOMINAL
OVERALL WIDTH18.240 INCHES NOMINAL
MAXIMUM OPERATING ALTITUDE RATING10000.0 FEET
MAXIMUM POWER DRAIN RATING250.0 WATTS
OPERATING AC FREQUENCY IN HERTZ47.0 MINIMUM SINGLE VOLTAGE AND 63.0 MAXIMUM SINGLE VOLTAGE
OPERATING CONTROL METHODMANUAL
OPERATING TEMP RANGE+0.0 TO 50.0 CELSIUS
PHASESINGLE
RELATIONSHIP TO SIMILAR EQUIPMENT6625010346118
SPECIAL FEATURESFRONT PANEL CONTROLS: PRIME POWER ON/OFF,RF OPERATE/STANDBY (FAULT RESET). FRONT PANEL INDICATORS: PRIME POWER ON/STANDBY,RF OPERATE,FAULT. METERING: HELIX CURRENT. PROTECTION: PRIME POWER FUSE,WARM UP DELAY,AUTOMATIC SEQUENCING OF HIGH VOLTAGE AND BEAM CURRENT,UNATTENDED PROTECTION (HEATER SHUTDOWN AFTER FAULT COUNTER TRIP),HELIX CURRENT OVERLOAD,HIGH TEMPERATURE LOW/HIGH LINE VOLTAGE,SAFETY INTERLOCKS. EQUIPMENT CASE,IS A SELF-CONTAINED DESIGNED FOR BENCH TOP OR RACK MOUNT. AUTO RECYCLE IF POWER OUTAGE IS LESSTHAN 3 SECONDS. AUTOMATIC TURN OFF IF TWO CONSECUTIVE HELIX OVERLOAD FAULTS OCCUR:NOISE FIGURE 35DB MAX: SPURIOUS MODULATION M50DBC MAX: LOAD VSWR 2.5:1 MAX: GAIN STABILITY 0.25DB/24HRS: MAXOPERATING HUMIDITY 95PCT