VENTILATION DESIGN TYPE | CONVECTION |
OVERALL WIDTH | 15.218 INCHES NOMINAL |
OVERALL HEIGHT | 5.187 INCHES NOMINAL |
OPERATING AMBIENT TEMP RANGE | 0.1 TO 60.0 DEG CELSIUS |
FEATURES PROVIDED | OVER VOLTAGE PROTECTOR AND |
| VOLTAGE ADJUSTMENT |
SPECIAL FEATURES | POWER ON-OFF SWITCH ON FRONT PANEL; REMOTE SENSING;METER MONITORS OUTPUT VOLTAGE/CURRENT BY MEANS OF VOLT/AMP SELECTOR SWITCH |
THE MANUFACTURERS DATA | |
MANUFACTURERS CODE | 53908 |
DESIGN CONTROL REFERENCE | 29111-02 |
INPUT VOLTAGE RATING | 105.0 AC VOLTS MINIMUM AND |
| 132.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
OVERALL LENGTH | 8.343 INCHES NOMINAL |
OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM AND |
| 40.0 DC VOLTS MAXIMUM SINGLE POWER OUTPUT |
OUTPUT CURRENT RATING | 2.7 DC AMPERES MINIMUM AND |
| 5.0 DC AMPERES MAXIMUM SINGLE POWER OUTPUT |
RIPPLE VOLTAGE AT FULL LOAD | 1.0 MILLIVOLTS PEAK SINGLE POWER OUTPUT |
OUTPUT CONTROL LOCATION | REAR PANEL SINGLE POWER OUTPUT |
OUTPUT CONNECTION QUANTITY | 1 SINGLE POWER OUTPUT |
OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM AND |
| 400.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
INPUT CONNECTION QUANTITY | 1 SINGLE OPERATING POWER RQMT |