INPUT VOLTAGE RATING | 240.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
OVERALL LENGTH | 330.0 MILLIMETERS NOMINAL |
OUTPUT VOLTAGE RATING | 225.00 AC VOLTS NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
OUTPUT CURRENT RATING | 500.0 AC VOLT-AMPERE NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
OUTPUT PHASE | SINGLE MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
OUTPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM AND |
| 60.0 HERTZ MAXIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
FREQUENCY REGULATION PERCENT | 0.5 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
OUTPUT WATTAGE RATING | 300.0 WATTS NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS | LIMITING CURRENT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
OUTPUT CONTROL TYPE | CURRENT LIMIT AND |
| VOLTAGE ADJUSTMENT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
OUTPUT CONNECTION QUANTITY | 4 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
INPUT CONNECTION QUANTITY | 1 SINGLE OPERATING POWER RQMT |
POWER SUPPLIES PROGRAMMED PER SYSTEM | 4 |
BATTERY FEATURE AND TYPE | RECHARGEABLE LEAD ACID CELL |
BATTERY LOCATION | INTERNAL |
BATTERY RECOVERY TIME | 300.0 |
MAXIMUM OPERATING ALTITUDE RATING | 3000.0 METERS |
OVERALL WIDTH | 90.0 MILLIMETERS NOMINAL |
OVERALL HEIGHT | 150.0 MILLIMETERS NOMINAL |
INSTALLATION DESIGN | BENCH |
OPERATING AMBIENT TEMP RANGE | 0.1 TO 30.0 DEG CELSIUS |
FEATURES PROVIDED | BATTERY CHARGER AND |
| CALIBRATED OUTPUT SIGNAL AND |
| CIRCUIT BREAKER AND |
| CIRCUIT OVERLOAD PROTECTION DEVICE AND |
| EMI FILTER AND |
| INPUT VOLTAGE RANGE SWITCH AND |
| OVER CURRENT PROTECTOR AND |
| VOLTAGE ADJUSTMENT |
SPECIAL FEATURES | INPUT VOLTAGE ADJUSTABLE IN FIVE INCREMENTS FROM A HIGH OF 220.0 TO 240.0 VAC, GREATER THAN 196.0 VAC, GREATER THAN 184.0 VAC, GREATER THAN 172.0 VAC, TO A LOW OF 160.0 VAC TO COMPENSA TE FOR BROWNOUT CONDITIONS; INPUT LINEUSES AN IEC 320 MALE APPLIANCE COUPLER; OPTION SWITCHES ALLOW FOR CUSTOMIZATION OF TRANSFER VOLTAGE (ON BATTERY) IN A STEPPED APPROXIMATION TO SINE WAVE AT 225.0 VAC PLUS OR MINUS 5 PERCENT, SET ALARM, AND CONTROL OUTPUT FREQUENCY SETTINGS; UNIT HAS 4 IEC FEMALE APPLIANCE COUPLERS; AMBIENT OPERATING HUMIDITY PLUS 0.0 TO 95.0 PERCENT (NON-CONDENSING); HOT SWAPPABLE USER-REPLACEABLE BATTERIES; WEIGHS 7.0 KG; LOW VOLTAGE DIRECTIVE 73/23/EEC, GS LICENSES BY VDE PER STANDARD EN60950 AND EN50091; EMC DIRECTIVE 89/336/EEC, C-TICK APPROVED, EN5022 (CISPR22) AND EN50082-1 |