2510-01-363-7363 STRUT ASSEMBLY,VEHICULAR SUSPENS Index 5995-01-363-7365 CABLE ASSEMBLY,SPECIAL PURPOSE,E

National Stock Number:
6145-01-363-7364

Federal Supply Class:
6145

National Item Identification Number:
013637364

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
J-C-58081348FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
J-C-580SO6CK10/14SRNJ81348FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
NO-10147R617WEICO WIRE & CABLE INC


Techincal Specification:
COLORBLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTORWHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTORRED 1ST POSITION PRIMARY INSULATION THIRD CONDUCTORGREEN 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTORORANGE 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTORBLUE 1ST POSITION PRIMARY INSULATION SIXTH CONDUCTORBROWN 1ST POSITION PRIMARY INSULATION SEVENTH CONDUCTORGRAY/GREY 1ST POSITION PRIMARY INSULATION EIGHTH CONDUCTORYELLOW 1ST POSITION PRIMARY INSULATION NINTH CONDUCTORVIOLET 1ST POSITION PRIMARY INSULATION TENTH CONDUCTORBLACK 2ND POSITION JACKET CABLE
CONDUCTOR ARRANGEMENT AND QUANTITY10 SINGLES
CONDUCTOR QUANTITY10
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CROSS SECTION OUTSIDE DIAMETER0.870 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORSRUBBER SYNTHETIC 1ST POSITION PRIMARY INSULATION ALL CONDUCTORSRUBBER NEOPRENE 2ND POSITION JACKET CABLE
ROUND CONDUCTOR SIZE14 AWG ALL CONDUCTORS
SPECIAL FEATURESFOURTH CONDUCTOR MAY HAVE OPTIONAL YELLOW TRACER
STRAND AWG SIZE PER CONDUCTOR30 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR41 ALL CONDUCTORS
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
TEMP RATING60.0 CELSIUS


Click here to Register for Free 30-day Trial