5985-01-373-6409 WAVEGUIDE ASSEMBLY Index 6145-01-373-6411 CABLE,POWER,ELECTRICAL

National Stock Number:
6145-01-373-6410

Federal Supply Class:
6145

National Item Identification Number:
013736410

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
E16C0-2-9SF81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
E16C0-9-2SF81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
SM-A-800634-2504569NATIONAL WIRE AND CABLE CORPORATION
SM-A-800634-2512515NEXANS AEROSPACE USA LLC
MIL-C-55021/281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-DTL-55021/281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
SM-A-800634-2512814AMPHENOL CABLE AND INTERCONNECT TECHNOLOGIES, INC.
SM-A-800634-2524027CALMONT ENGINEERING & ELECTRONICS CORP.
SM-A-800634-2580063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
COLORBLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTORWHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTORRED 1ST POSITION PRIMARY INSULATION THIRD CONDUCTORWHITE OR NATURAL 3RD POSITION JACKET CABLE
CONDUCTOR ARRANGEMENT AND QUANTITY1 TRIPLES
CONDUCTOR QUANTITY3
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CROSS SECTION OUTSIDE DIAMETER0.241 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B298 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORSASTM B298 ASSN STD SINGLE MATERIAL RESPONSE 2ND POSITION SHIELD BRAID, METALLIC CABLE
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORSPLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORSCOPPER 2ND POSITION SHIELD BRAID, METALLIC CABLEPLASTIC FLUORINATED ETHYLENE PROPYLENE 3RD POSITION JACKET CABLE
PRECIOUS MATERIAL AND LOCATIONSURFACE ALL CONDUCTORS SILVER AND SURFACE SHIELD BRAID SILVER
PRECIOUS MATERIALSILVER
ROUND CONDUCTOR SIZE16 AWG ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR29 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B298 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORSASTM B298 ASSN STD SINGLE TREATMENT RESPONSE 2ND POSITION SHIELD BRAID, METALLIC CABLE
SURFACE TREATMENTSILVER CORE CONDUCTOR ALL CONDUCTORSSILVER 2ND POSITION SHIELD BRAID, METALLIC CABLE
TEMP RATING-65.0 CELSIUS AND 200.0 CELSIUS


Click here to Register for Free 30-day Trial