BINDING METHOD | SEALING TAPE |
BRANCH QUANTITY | 2 |
CABLE ASSEMBLY OVERALL LENGTH | 31.000 INCHES NOMINAL |
CONDUCTOR QUANTITY | 3 |
PART NAME ASSIGNED BY CONTROLLING AGENCY | CABLE ASSY - FAN |
MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR ALL CONDUCTORS |
MATERIAL | COPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS |
SPECIAL FEATURES | TWO BRANCHES WITH UNPROCESSED ENDS THAT START 4.000 INCHES FROM THE 2ND END; ONE BRANCH MEASURES 13.000 INCHES AND THE OTHER MEASURES 12.000 INCHES. A CAPACITOR IS SPLICED INTO THE SINGLE CONDUCTOR 12.000 INCHES FROM THE 2ND END |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS |
TERMINAL LUG APERTURE SIZE | 0.500 INCHES 1ST END SINGLE CONDUCTOR |
TERMINATION TYPE | UNPROCESSED 2ND END ALL CONDUCTORS |
TERMINATION TYPE | LUG TERMINAL W/MOUNTING HOLE 1ST END SINGLE CONDUCTOR |