5610-00-004-9531 SAND,DENSITY TEST Index 4820-00-004-9537 VALVE,PRESSURE EQUALIZING,GASEOU

National Stock Number:
6625-00-004-9536

Federal Supply Class:
6625

National Item Identification Number:
000049536

Description:
MULTIMETER

Detail:
An instrument which is arranged to measure two or more different electrical quantities (such as volts, amps, and ohms) by means of associated circuits and switches. The value is usually expressed on a single calibrated dial or digital readout display. For items which are connected into a circuit and used chiefly to visually monitor an operation, see METER, MULTIPLE SCALE. See also COUNTER, ELECTRONIC, DIGITAL READOUT. Excludes BRIDGE (as modified).


Manufacturer Information:
260-6P55026SIMPSON ELECTRIC COMPANY, INC.


Techincal Specification:
ACCURACY IN PERCENT-1.5 TO 1.5 AT FULL SCALE SINGLE INDICATOR 6TH RANGE
ACCURACY IN PERCENT-2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR 1ST RANGE
ACCURACY IN PERCENT-2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR 3RD RANGE
ACCURACY IN PERCENT-2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR 4TH RANGE
ACCURACY IN PERCENT-2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR 5TH RANGE
ACCURACY IN PERCENT-3.0 TO 3.0 AT FULL SCALE SINGLE INDICATOR 2ND RANGE
BACKGROUND COLORWHITE SINGLE INDICATOR ALL RANGES
CIRCUIT CURRENT FOR WHICH DESIGNEDDC
CIRCUIT ATTACHMENT METHOD AND QUANTITY2 WIRE LEAD
DIAL SCALE MARKING COLORBLACK SINGLE INDICATOR 1ST RANGE
DIAL SCALE MARKING COLORBLACK SINGLE INDICATOR 3RD RANGE
DIAL SCALE MARKING COLORBLACK SINGLE INDICATOR 4TH RANGE
DIAL SCALE MARKING COLORBLACK SINGLE INDICATOR 5TH RANGE
DIAL SCALE MARKING COLORBLACK SINGLE INDICATOR 6TH RANGE
DIAL SCALE MARKING COLORRED SINGLE INDICATOR 2ND RANGE
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS1000.0
FURNISHED ITEMS AND QUANTITYLEADS,TEST 2;BATTERIES 2;MANUAL 1
FREQUENCY RESPONSE RANGE+0.020 TO 50.000 KILOHERTZ
INDICATOR TYPEDIAL W/POINTER
INSTALLATION DESIGNHAND HELD
OVERALL DEPTH3.125 INCHES NOMINAL
OVERALL LENGTH7.000 INCHES NOMINAL
OVERALL WIDTH5.250 INCHES NOMINAL
MATERIALPLASTIC PHENOLIC
MEASUREMENT RANGE+0.0 TO 10.0 AMPERES, DC SINGLE INDICATOR 3RD RANGE
MEASUREMENT RANGE+0.0 TO 1000.0 VOLTS, AC SINGLE INDICATOR 2ND RANGE
MEASUREMENT RANGE+0.0 TO 1000.0 VOLTS, DC SINGLE INDICATOR 1ST RANGE
MEASUREMENT RANGE+0.0 TO 20.0 MEGOHMS SINGLE INDICATOR 4TH RANGE
MEASUREMENT RANGE+0.0 TO 50.0 MICROAMPERES, DC SINGLE INDICATOR 6TH RANGE
MEASUREMENT RANGE+0.0 TO 500.0 MILLIAMPERES, DC SINGLE INDICATOR 5TH RANGE
MOVEMENT SUSPENSION METHODTAUT BAND
MOVEMENT TYPEMOVING COIL, PERMANENT MAGNET
NUCLEAR HARDNESS CRITICAL FEATURENONHARDENED
POINTER COLORRED SINGLE INDICATOR ALL RANGES
POWER SOURCEINTERNAL
SCALE DIVISION QUANTITY50 SINGLE INDICATOR 1ST RANGE
SCALE DIVISION QUANTITY50 SINGLE INDICATOR 2ND RANGE
SCALE DIVISION QUANTITY50 SINGLE INDICATOR 3RD RANGE
SCALE DIVISION QUANTITY50 SINGLE INDICATOR 5TH RANGE
SCALE DIVISION QUANTITY50 SINGLE INDICATOR 6TH RANGE
SCALE GRADUATION TYPELINEAR SINGLE INDICATOR 1ST RANGE
SCALE GRADUATION TYPENONLINEAR SINGLE INDICATOR 4TH RANGE
SCALE GRADUATION TYPELINEAR SINGLE INDICATOR 2ND RANGE
SCALE GRADUATION TYPELINEAR SINGLE INDICATOR 3RD RANGE
SCALE GRADUATION TYPELINEAR SINGLE INDICATOR 5TH RANGE
SCALE GRADUATION TYPELINEAR SINGLE INDICATOR 6TH RANGE
SCALE SELECTION METHODSWITCH
SENSITIVITY RATING1000.0 OHMS PER VOLT
SPECIAL FEATURESOHMS ACCURACY IS PORM 1 DEG. OF ARC;MEASURES FROM NEG. 20 TO POS. 50 DECIBLES
STYLE DESIGNATORPORTABLE


Click here to Register for Free 30-day Trial